The power unit drives the plunger pump in WHPVMF to realize the conversion from mechanical energy to hydraulic energy; the hydraulic energy to mechanical energy through the plunger motor, so as to provide torque for the executing element. The plunger pump and plunger motor form a closed cycle, and the leaking oil is supplied by the filling pump. The output shaft of the plunger motor drives the walking device to realize the functions of forward, stopping and backward of the machine.

 

Size 28 32 37 42 47
Displacement Pump Vg max ml/r 28 32 37 42 47
Motor Vg max ml/r 28 32 37 42 47
Boost Pump Vg max ml/r 7 7.2 7.3 10 10
Rotation Input n max r/min 3000
Output n max r/min 0–3000
Flow (Max) When n max 时L/min 84 96 111 126 141
When n=1500 L/min 42 48 55.5 63 70.5
Torque (Max) When Vg max△P=28Mpa 124.7 142.5 164.7 186.9 209.2
When Vg max △P=10Mpa 44.5 50.9 58.8 66.8 74.7
Power (Max) nmax Pmax KWWhen n in max 39.2 44.8 51.8 58.7 65.7
n=1500r/min Pmax KWWhen n=1500r/min 19.6 22.4 25.9 29.4 32.9
Case valume L 0.8 0.81 0.84 0.85 0.88
Weight KG 22.5 23 27.5 28 29.5